SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
111
Topology rules for DRIVE-CLiQ
6
Topology rules for DRIVE-CLiQ
There are fixed DRIVE-CLiQ topology rules for the S120 Combi. These rules must be
observed. If violated, then a corresponding alarm is displayed.
Assigning the DRIVE-CLiQ interfaces
Table 6- 1 Assigning the DRIVE-CLiQ interfaces on the S120 Combi
DRIVE-CLiQ interface Connection with
X200 X100 of the PPU
X201 Motor encoder, spindle
X202 Motor encoder, feedrate 1
X203 Motor encoder, feedrate 2
X204 Motor encoder, feedrate 3 -> only for 4 axes Power Module
remains empty for 3 axes Power Module
X205 Optional: 2. Direct sin/cos encoder for spindle (via SMx20)
1)
remains empty when a direct TTL spindle encoder is connected via X220
1) in this case, the TTL encoder interface X220 remains free
Table 6- 2 Assigning the DRIVE-CLiQ interfaces to the SINUMERIK 828D (PPU)
DRIVE-CLiQ interface Connection with
X100 X200 of the S120 Combi
X101 X200 of a Single Motor Module or Double Motor Module
X102 X500 of the Terminal Module TM54F
X500 of the Hub Modules (DMx20)
1)
1) when using a TM54F, the DMx20 is connected in series at the TM54F via the DRIVE-CLiQ interface X501