Motor Modules Booksize Compact as expansion axes
7.8 Technical data
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
133
7.8 Technical data
Table 7- 9 Technical data Single Motor Modules Booksize Compact (3 A to 18 A)
Single Motor Modules Booksize Compact 6SL3420– 1TE13-0AAx 1TE15-0AAx 1TE21–0AAx 1TE21–8AAx
Output current
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
s6
) 40%
Peak current (I
max
)
A
ACrms
A
A
ACrms
A
ACrms
3
2.6
3.5
9
5
4.3
6
15
9
7.7
10
27
18
15.3
24
54
Output voltage V
ACrms
0 - 0.717 x DC link voltage
DC link current I
d
A
DC
3.6 6 11 22
DC link voltage
(up to 2000 m above sea level)
V
DC
510 – 720
DC link capacitance μF 110 110 110 235
Overvoltage tripping
Undervoltage tripping
1)
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Electronics power supply V
DC
24 (20.4 - 28.8)
Electronics current consumption at 24 V DC A
DC
0.85 0.85 0.85 0.85
Current carrying capacity
DC link busbar
Reinforced DC link busbars
24 V busbar
A
DC
A
DC
A
DC
100
150
20
100
150
20
100
150
20
100
150
20
Max. current motor brake A 2 2 2 2
Unit rating
Based on I
n
(600 V
DC
; 4 kHz)
Based on I
H
kW
kW
1.6
1.4
2.7
2.3
4.8
4.1
9.7
13.7
Total power loss
(including electronics losses)
2)
W 68
at 8 kHz
98
at 8 kHz
100.4
at 4 kHz
185.4
at 4 kHz
Max. pulse frequency
Without derating
With derating
kHz
kHz
8
16
8
16
4
16
4
16
Max. ambient temperature
Without derating
With derating
°C
°C
40
55
Sound pressure level dB(A) <60 <60 <60 <60
Cooling method Internal air
cooling
Cooling air requirement m
3
/h 29.6 29.6 29.6 29.6
Weight kg 2.7 2.7 2.7 3.4
1) Default for 400 V line supplies; undervoltage trip threshold can be reduced by a maximum of 80 V and is adjusted to the
parameterized line voltage.
2) For an overview, see the power loss tables in chapter Control cabinet installation