3.3 Interface description
SINAMICS S120 Combi
72 Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
DANGER
Risk of electric shock!
Only temperature sensors that meet the safety isolation specifications contained in
EN 61800-5-1 may be connected to terminals "+Temp" and "-Temp".
If these instructions are not complied with, there is a risk of electric shock!
NOTICE
The KTY temperature sensor must be connected with the correct polarity.
If the polarity is reversed, the sensor will not be able to detect if the motor overheats.
NOTICE
The function of the EP terminals is only available when Safety Integrated Basic Functions
are enabled.
Note
The temperature sensor input is not needed if the motors feature an integrated DRIVE-CLiQ
interface or if temperature values are detected by means of a different module (SMC, SME).
3.3.7 X200-X205 DRIVE-CLiQ interfaces
Table 3- 11 X200-X205 DRIVE-CLiQ interfaces
PIN Signal name Technical specifications
1 TXP Transmit data +
2 TXN Transmit data -
3 RXP Receive data +
4 NC
5 NC
6 RXN Receive data -
7 NC
8 NC
A + (24 V) Power supply
B M (0 V) Electronics ground
Connector
type
RJ45 socket
The blanking covers for the DRIVE-CLiQ interfaces are included in the scope of delivery.
Blanking covers (50 pieces) Order number: 6SL3066-4CA00-0AA0