Motor Modules Booksize Compact as expansion axes
7.8 Technical data
SINAMICS S120 Combi
138 Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
3HUPLVVLEOHRXWSXWFXUUHQW
,QVWDOODWLRQDOWLWXGHDERYHVHDOHYHO







>@



>P@

Figure 7-18 Output current as a function of the installation altitude
3HUPLVVLEOHRXWSXWFXUUHQW
,
Q
,
+
,
6
,
PD[
2XWSXWIUHTXHQF\




  +]
Figure 7-19 Current derating as a function of the output frequency
At installation altitudes >2000 m, an insolating transformer must be used (see "System
overview/Derating as a function of the installation altitude and ambient temperature"). The
design of the secondary line supply system must be as follows:
TN system with grounded star point (no grounded outer conductor)
IT system
A reduction of the line supply voltage phase-phase is not necessary.