Cabinet design and EMC
13.7 Connection system
SINAMICS S120 Combi
Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
249
Table 13- 7 Comparison between MOTION-CONNECT 500 and MOTION-CONNECT 800PLUS DRIVE-CLiQ cables
DRIVE-CLiQ signal cable MOTION-CONNECT 500 MOTION-CONNECT 800PLUS
Approvals
VDE
cURus or UR/CSA
UR-CSA File No.
1)
in conformance with RoHS
Yes
UL STYLE 2502/CSA-N.210.2-M90
Yes
Yes
Yes
UL STYLE 2502/CSA-N.210.2-M90
Yes
Yes
Rated voltage V
0
/V
in accordance with EN 50395
30 V 30 V
Test voltage, rms 500 V 500 V
Operating temperature at the surface
Permanently installed
Moveable
-20 to +80°C
0 to 60°C
-20 to +80°C
-20 to +60°C
Tensile load, max.
Permanently installed
Moveable
80 N/mm
2
30 N/mm
2
50 N/mm
2
20 N/mm
2
Smallest bending radius
Permanently installed
Moveable
35 mm
125 mm
35 mm
75 mm
Torsional stress 30°/m absolute 30°/m absolute
Bending operations 100000 10 million
Max. traversing speed 30 m/min 300 m/min
Max. acceleration 2 m/s
2
Up to 50 m/s
2
(3 m)
insulation material CFC/silicone-free CFC/halogen-free/silicon-free
Oil resistance EN 60811-2-1
(mineral oil only)
EN 60811-2-1
Protective jacket PVC PUR, HD22.10 S2
(VDE 0282, Part 10)
Flame retardant EN 60332-1-1 to 1-3 EN 60332-1-1 to 1-3
1) The file number is printed on the cable jacket.