S120 Combi Power Modules
3.3 Interface description
SINAMICS S120 Combi
76 Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
Cable length as a function of the encoder current for encoders with 5 V supply (valid for cable cross-
sections with 0.5 mm
2
):











(QFRGHUSRZHU
&DEOHOHQJWK>P@
Figure 3-8 Max. cable length as a function of the encoder current drawn
For encoders without Remote Sense the permissible cable length is restricted to 100 m
(reason: the voltage drop depends on the cable length and the encoder current).