S120 Combi Power Modules
3.9 Technical data
SINAMICS S120 Combi
92 Manual, Edition 07/2012, 6SL3097-4AV00-0BP3
3 axes Power Modules 6SL3111- 3VE21-6FA0 3VE21-6EA0 3VE22-0HA0
Feedrate 2
Output current
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current (I
S6
) 40%
Peak current (I
max
)
A
ACrms
A
ACrms
A
ACrms
A
ACrms
5
4.3
6.5
10
9
7.7
12
18
9
7.7
12
18
Rated power
at 540 V DC link voltage
at 600 V DC link voltage
kW
kW
2.4
2.7
4.3
4.8
4.3
4.8
Pulse frequency feedrate 2 kHz 4
Output voltage V
ACrms
0 - 0.7 x DC link voltage
Output for expansion axis
DC link voltage V
DC
460 – 720
DC link output current (I
n
) A
DC
40
Max. electronics output current for
expansion axis
A
24Vmax
20
General data
Electronics current consumption at 24 V
DC
without external fan unit
with external fan unit
A
A
1.5
2.3
1.5
2.3
1.5
2.3
Total power loss
2)
(including electronics losses)
3)
internal
external
W
W
W
425
81
344
537
91
446
634
102
532
Max. ambient temperature
Without derating
With derating
°C
°C
45
55
45
55
45
55
DC link voltage V
DC
460 – 720
DC link capacitance μF 1645 1880 2115
Overvoltage tripping
Undervoltage tripping
V
DC
V
DC
820 ± 2 %
380 ± 2 %
Circuit breaker (UL)
Type designation
Rated current:
Resulting rated
short-circuit current SCCR at 480 V
AC
A
kA
3VL2105-2KN30
50
65
3VL2105-2KN30
50
65
3VL2106-2KN30
60
65
Fuses (UL)
Type AJT Class J
4)
Rated current
Resulting rated
short-circuit current SCCR
at 480 V
AC
at 600 V
AC
A
kA
kA
AJT 35
35
65
200
AJT 35
35
65
200
AJT 60
60
65
200
Cooling method External air cooling