Hydro:Evolved User Manual
October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 107
From the ACCESS CODE menu, scroll and select CCB Timer.
Figure 134: ACCESS CODE Menu – CCB Timer
From the CCB TIMER menu, set the time the user has to enter each digit of the access
code.
Figure 135: CCB TIMER Menu
Scroll right and press Save.
12.5 Enable Releveling
Load weight and velocity are calibrated when setting the landing point of a car. When the
position indicator sends a signal that the position of the landing point of the car is not equal to
the landing floor, the landing point has to be recalibrated.
The following procedure describes how to enable releveling.
Navigate to MAIN MENU | SETUP | FLOORS. See Figure 55.
From the FLOORS menu, scroll and select Enable Releveling.
Figure 136: FLOORS Menu – Enable Releveling
From the ENABLE RELEVELING menu, select if releveling is enabled.
Figure 137: ENABLE RELEVELING Menu
Scroll right and press Save.