Hydro:Evolved User Manual
Page 298 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
From the NUMBER XREG CARS menu, enter the number of cars from the legacy system.
Figure 582: NUMBER XREG CARS Menu
Scroll right and press Save.
34.2 XReg Destination Timeout
If a car has been assigned a cross registration destination and does not answer within in a
period of time, the car is taken out of the group until the cross-registration timeout has
elapsed.
The following procedure describes the how to set the cross-registration timeout.
Navigate to MAIN MENU | SETUP | GROUP SETUP. See Figure 58.
From the GROUP SETUP menu, scroll and select XReg Destination Timeout.
Figure 583: GROUP SETUP Menu XReg Destination Timeout
From the XREG DESTINATION TIMEOUT menu, set the time for a cross registration car to
answer a car call prior to another car responding. If set to zero, this feature is disabled.
Figure 584: XREG DESTINATION TIMEOUT Menu
Scroll right and press Save.
34.3 XReg Destination Offline Timeout
The cross registration offline timeout is the time a car is out of the group due to not answering
hall calls.
The following procedure describes cross registration destination offline timeout.
Navigate to MAIN MENU | SETUP | GROUP SETUP. See Figure 58.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals