Hydro:Evolved User Manual
October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 133
From the NUDGE BUZZER ONLY menu, scroll and select ON if the buzzer sounds when
nudging.
Figure 221: NUDGE BUZZER ONLY Menu
Scroll right and press Save.
14.22 Opening Time
The opening time is the time for a door to go from fully closed to fully open. This allows the
controller to estimate door opening time for use during preflight operation.
The following procedure describes how to set the time to fully open the doors.
Navigate to MAIN MENU | SETUP | DOOR SETUP. See Figure 55.
From the DOORS menu, scroll and select Opening Time.
Figure 222: DOORS Menu Opening Time
From the OPENING TIME menu, set the time for the doors to fully open.
Figure 223: OPENING TIME Menu
Scroll right and press Save.
14.23 Check Time
The check time is the configured amount of time that the doors need to be considered safe
before the car is allowed to run on automatic operation.
The following procedure describes how to set the check time.
Navigate to MAIN MENU | SETUP | DOOR SETUP. See Figure 55.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals