October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 193
Scroll right.
Scroll and select the desired input or output. Figure 350 shows the Auto Operation
category to assign Car to Lobby to an unused input.
Scroll right and press Save.
20.2 Removing an Input or Output
The following procedure describes how to remove an input or output.
Navigate to MAIN MENU | SETUP | SETUP I/O. See Figure 33.
From the SETUP I/O menu, select Setup Inputs or Setup Outputs. See Figure 158.
NOTE: The input and output steps are the same.
From the SELECT BOARD menu, select which board the input or output is being removed
from. See Figure 159.
Scroll and select the input or output to be removed. See Figure 350.
Scroll right.
Scroll and select the current input or output to unused.
Scroll right.
Scroll and select the desired category of the input/output to unused.
Scroll right and press Save.
20.3 Types of Inputs
The tables below list the definitions for the types of inputs per category.
Table 30: Description of Auto Operation Inputs
When active, attendant operation causes the car to skip past all
hall calls between its current position and current destination.