Hydro:Evolved User Manual
Page 296 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
From the GROUP LANDING OFFSET menu, set the number of floors below a group that
are serviced by another group.
Figure 576: GROUP LANDING OFFSET Menu
Scroll right and press Save.
33.3 Dispatch Timeout
The dispatch timeout is a set time a car has to answer a hall call. If time has elapsed, the car is
taken out of group and the call is reassigned to another car.
The following procedure describes how to set the dispatch timeout.
Navigate to MAIN MENU | SETUP | GROUP SETUP. See Figure 58.
From the GROUP SETUP menu, scroll and select Dispatch Timeout.
Figure 577: GROUP SETUP Menu Dispatch Timeout
From the DISPATCH TIMEOUT menu, set the time the car has to answer a car call prior
to another car responding. A setting of 0 disables this feature.
Figure 578: DISPATCH TIMEOUT Menu
Scroll right and press Save.
33.4 Dispatch Offline Timeout
The dispatch offline timeout sets the time a car is out of the group due to not responding to a
hall call.
The following procedure describes how to set the dispatch offline timeout.
Navigate to MAIN MENU | SETUP | GROUP SETUP. See Figure 58.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals