Hydro:Evolved User Manual
Page 44 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
The table below lists the Setup Speeds, Floors, and Hoistway Access menu structures.
Table 17: Setup Speeds, Floors, and Hoistway Access Menu Structures
Menu
Description
Setup
Speeds
Configure speed parameters
Floors
Configure floor related parameters
Hoistway Access
Hoistway access setup menu
Speeds
Contract Speed
Maximum speed of the elevator
Inspection speed
Set the speed at which the car runs for all inspection
modes
Leveling Speed
Sets the speed used in automatic operation when
leveling into a floor. If leveling distance is zero, this has
no effect.
Test Buffer Speed
Sets the speed used during buffer test
Floors
Number Of Floors
Allows for setting the number of floors within the
building
Too High/ Too Low
Used to adjust the learned position of the floor when
setting floor levels
Enable Releveling
Enables releveling operation
Relevel Zone Size
Sets the size of the releveling zone (dead zone)
Releveling Delay
The time the controller waits before engaging a Relevel
command while in a door zone and outside the dead
zone
Openings (F)
Allows for setting the floors the front door opens
Openings (R)
Allows for setting the floors the rear door opens
Security (F)
Allows for setting the security parameters for front door
Security (R)
Allows for setting the security parameters for rear door
Store Floor Level
Sets the position of the short floor level
Short Floor Opening
Sets overlapping door zones (short floors)
Time CC Security
Allows for setting security for specific times
Time CC Security
Enable Floor (F)
Allows for enabling timed security for front openings
Enable Floor (R)
Allows for enabling timed security for rear openings
Start (M-F)
Sets the time that floor access is denied during M-F
Stop (M-F)
Sets the time that floor access is resumed on M-F
Start (S-S)
Sets the time that floor access is denied during S-S
Stop (S-S)
Sets the time that floor access is resumed on S-S

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals