Hydro:Evolved User Manual
Page 44 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
The table below lists the Setup – Speeds, Floors, and Hoistway Access menu structures.
Table 17: Setup – Speeds, Floors, and Hoistway Access Menu Structures
Configure speed parameters
Configure floor related parameters
Hoistway access setup menu
Maximum speed of the elevator
Set the speed at which the car runs for all inspection
modes
Sets the speed used in automatic operation when
leveling into a floor. If leveling distance is zero, this has
no effect.
Sets the speed used during buffer test
Allows for setting the number of floors within the
building
Used to adjust the learned position of the floor when
setting floor levels
Enables releveling operation
Sets the size of the releveling zone (dead zone)
The time the controller waits before engaging a Relevel
command while in a door zone and outside the dead
zone
Allows for setting the floors the front door opens
Allows for setting the floors the rear door opens
Allows for setting the security parameters for front door
Allows for setting the security parameters for rear door
Sets the position of the short floor level
Sets overlapping door zones (short floors)
Allows for setting security for specific times
Allows for enabling timed security for front openings
Allows for enabling timed security for rear openings
Sets the time that floor access is denied during M-F
Sets the time that floor access is resumed on M-F
Sets the time that floor access is denied during S-S
Sets the time that floor access is resumed on S-S