Hydro:Evolved User Manual
Page 60 © 2022 Smartrise Engineering, Inc. All Rights Reserved October 2022
The table below lists the Setup – Hydro and Access menu structures.
Table 22: Setup – Hydro and Access Menu Structures
Allows the user to choose the type of valve used in the
system
Checks for secondary Valve board when set to ON at
startup
Allows the user to select soft starter options
Sets the maximum run distance when the medium
valve speed run is selected. Longer runs will use the
next higher speed valve. When set to zero, the valve is
disabled.
Sets the maximum run distance when the low valve
speed run is selected. Longer runs will use the next
higher speed valve. When set to zero, the valve is
disabled.
Sets the maximum run distance when the level valve
speed run is selected. Longer runs will use the next
higher speed valve. When set to zero, the valve is
disabled.
Distance added to the slowdown distance to cut off
high valves in the up direction
Distance added to the slowdown distance to cut off
high valves in the down direction
Distance from the destination position that the car cuts
its leveling valve when moving in the up direction on a
non-releveling run
Distance from the destination position that the car cuts
its leveling valve when moving in the down direction on
a non-releveling run
Distance from the destination position that the car cuts
its leveling valve when moving in the up direction on a
releveling run
Distance from the destination position that the car cuts
its leveling valve when moving in the down direction on
a releveling run
Positioning system speed feedback is used for this
comparison
Distance when the car starts slowing down on a normal
run while moving in up direction