EasyManuals Logo

Smartrise HYDRO:EVOLVED User Manual

Default Icon
357 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #95 background imageLoading...
Page #95 background image
Hydro:Evolved User Manual
October 2022 © 2022 Smartrise Engineering, Inc. All Rights Reserved Page 61
Menu
Description
Slowdown Dist. DN
Distance when the car starts slowing down on a normal
run while moving in down direction
Battery Test Time
Sets the time to check the battery board
Jack Resync Time
Sets the time to trigger Jack Resync
DISA NTS Alarm
Disables NTS alarms
TSRD Distance
Sets the distance to prevent car from hitting the buffer
Soft Starter
ENA SR Soft Starter
Enables soft starter board
Primary
Enables primary soft starter
Secondary
Enables secondary soft starter
Run With One SS
When set to ON, if two soft starters are supported, and
only one of those soft starters is faulted, the car will still
be allowed to run.
Primary
Ramp Up Time
Sets the primary soft starter time to ramp up to V-Max
Vmax
Sets the primary soft starter percentage of input AC
voltage used for ramp up
Over Current
Sets the primary soft starter overcurrent limit in amps
Over Temperature
Sets the primary soft starter over temperature limit in
degrees Fahrenheit counts
Secondary
Enable Secondary
Enables secondary soft starter
Ramp Up Time
Sets the secondary soft starter time to ramp up to V-
Max
Vmax
Sets the secondary soft starter percentage of input AC
voltage used for ramp up
Over Current
Sets the secondary soft starter overcurrent limit in
amps
Over Temperature
Sets the secondary soft starter over temperature limit
in degrees Fahrenheit counts
Hydro Speed Setup
Up Adjustments
Adjust speed when transitioning from contract speed to
leveling speed in the up direction
Down Adjustment
Adjust speed when transitioning from contract speed to
leveling speed in the down direction
Generate Thresholds and Distance
Updates threshold and slowdown distances based on
adjustment settings
Access Code
Access Code (F)
Code that gives access to front door car calls
Access Code (R)
Code that gives access to rear door car calls
CCB Timer
Time for registering a car call after access code is
entered

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish