The following procedure describes how to set the car to stop randomly at different landings.
Navigate to MAIN MENU | DEBUG | DEBUGRUNS. See Figure 66.
From the DEBUGRUNS menu, scroll and select Random.
Figure 635: DEBUGRUNS Menu Random
From the RANDOM menu, scroll and select if checking front or rear doors during a
random run.
Figure 636: RANDOM Menu Front or Rear
From the RANDOM RUNS (FRONT or REAR) menu, scroll and select if enabling the car to
stop at random floors with the doors that only open from the front or rear.
Figure 637: RANDOM RUNS FRONT Menu
Figure 638 RANDOM RUNS REAR Menu
Scroll right and press Save.
38.12.5 Hall Random Runs
Hall random runs allow random hall calls to be initiated. The mask set in this menu is used to
generate hall calls to simulate hall board requests. See section 16.8 Hall Call Masks.
The following procedure describes how to set the car to stop on a floor by the randomly
selected hall call.
Navigate to MAIN MENU | DEBUG | DEBUGRUNS. See Figure 66.

Table of Contents

Other manuals for Smartrise HYDRO:EVOLVED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Smartrise HYDRO:EVOLVED and is the answer not in the manual?

Smartrise HYDRO:EVOLVED Specifications

General IconGeneral
BrandSmartrise
ModelHYDRO:EVOLVED
CategoryController
LanguageEnglish

Related product manuals