Chapter 8 - Maintenance
8.8.3.2. CASE 2
• Check 5V on STARC (see chapter 8.9, page 232).
• Check wiring between STARC J302 and RSI J100.
• Change the RSI.
8.8.3.3. CASE 3
• Refer to STARC chapter (8.9) if there is an error message from STARC (STARC has the
possibility to shut off 5V on RSI in case of major error).
• Check wiring between STARC J302 and RSI J100.
• Change the RSI.
Problem:
D52 remains off (5V from STARC).
Solution:
Problem:
D52 is on and D50 remains off.
Solution:
?
?