Depressurising the hydraulic circuits for
the "5th and 6th hydraulic function"
If the truck has a "5th and 6th hydraulic func-
tion", their hydraulic circuits must also be dep-
ressurised. The procedure is similar to the de-
pressurisation of the hydraulic circuits for the
basic functions and the additional functions. In
addition, the hydraulic circuits are depressur-
ised in the same way as the attachments are
operated. The hydraulic circuits for the
"5th and 6th hydraulic functions" are actuated
via the corresponding buttons on the operating
devices.
– Press the button (1) and hold it down.
– Push the operating lever (4) once in the di-
rection of the arrow until the end position is
reached.
The hydraulic circuit of the 5th hydraulic func-
tion is depressurised. The plug connectors on
the lift mast are depressurised.
– Press the button (2) and hold it down.
– Push the operating lever (3) once in the di-
rection of the arrow until the end position is
reached.
The hydraulic circuit of the 6th hydraulic func-
tion is depressurised. The plug connectors on
the lift mast are depressurised.
Completing the depressurisation
– To complete the depressurisation, observe
the section entitled "Exiting the wizard".
Depressurising the hydraulic sys-
tem using a double mini-lever
– Start the "wizard for depressurising the hy-
draulic system".
6219_003-252
4
3
1
2
Operation
4
Depressurising the hydraulic system
286 56368011531 EN - 01/2021 - 05