Maintenance personnel for batteries
Batteries must only be charged, serviced, and
replaced by personnel who have received ap-
propriate training in accordance with the in-
structions from the manufacturers of the bat-
tery, battery charger and truck.
– Observe the handling instructions for the
battery and the operating instructions for
the battery charger.
Maintenance work by the operating
company
All of the required inspection points for 150-
hour maintenance by the operating company
are listed in this chapter in the section entitled
"Maintenance by the operating company: Ex-
plosion-protection components - 150 hours/
monthly".
– If you have any questions about this, please
contact your authorised service centre.
Maintenance work without special quali-
fications
Simple maintenance work, such as checking
the hydraulic oil level, may be carried out by
untrained personnel. A qualification of the type
held by a competent person is not required to
carry out this work. The required tasks are de-
scribed in the chapter entitled "Preserving op-
erational readiness".
Maintenance of the explosion pro-
tection components
The explosion protection components of the
truck must be tested on a regular basis, but no
later than after the "explosion-protection check
" has been performed according to the "work-
shop manual" and the latest technological
standard, and according to the applicable
standards and regulations for conversion. The
elements for the maintenance and repair of
the electrical system are listed in the standard
"DIN EN 60079-17:2014-10".
Maintenance
5
General maintenance information
44556368011531 EN - 01/2021 - 05