Place of use
DANGER
There is a risk of explosion during use
in potentially explosive areas.
The truck may only be operated in the
potentially explosive areas for which it is
approved!
– Check the area of application by com-
paring it with the nameplate informa-
tion.
– If the area of application is not clear,
ask the safety officer.
DANGER
Risk of explosion when brushing against equip-
ment!
If conductive components of the truck come into con-
tact with flexible doors or strip curtains, dangerous
electrostatic charges can form.
– Avoid electrostatic charges.
DANGER
Risk of explosion when using without conductive
flooring!
The truck must only be operated in potentially explo-
sive areas that are fitted with conductive flooring.
– Avoid electrostatic charges.
NOTE
More information concerning the requirements
for conductive or dissipative floorings can be
found in the guidelines relating to electrostatic
hazards "CLC/TR 60079-32-1".
The truck is approved in accordance with Di-
rective 2014/34/EU for use in potentially ex-
plosive areas. These areas are specified on
the nameplate. In such areas, the safety offi-
cer must approve access by the truck.
Relationship between zones and equipment
categories for industrial trucks
●
Zone 1 – category 2G
Use is permitted in areas where hazardous,
potentially explosive atmospheres may
Foreword
1
Using the truck
26 56368011531 EN - 01/2021 - 05