Nameplate of the pressure-tight
housing
The flame proof enclosures are marked with a
nameplate. The data on the plate corresponds
to the approved area of application for the
flame proof enclosure. The plate must be posi-
tioned so that it is always easy to read. Only
the manufacturer is allowed to re-label the
flame proof enclosures.
Various notes are printed on the plate:
●
"Cable entries: see instructions"
●
"Use screws quality 8.8 or better"
●
"Do not open when energised"
●
"Do not open when an explosive atmos-
phere may be present"
A warning sign is located in the immediate vi-
cinity of the nameplate:
●
"Open only in a non-potentially explosive at-
mosphere"
5060_901-020_V2
0044
S.r.l.
(I) 20812 LIMBIATE (MB) ‒ Via Marconi, 31
CBH ‒ 5 II 573714 3
CEC 14 ATEX 043X T.amb. = ‒20°C to + 60°C
Ex d
ia
6
IIC T Gb
[
[
s/n Year 20
/
T cable °C
Ex tb
CABLE ENTRIES : SEE INSTRUCTIONS
USE SCREWS QUALITY 8.8 OR BETTER
DO NOT OPEN WHEN ENERGIZED
DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE MAY BE PRESENT
IIIC T
II 2 (1) GD
°C Db IP66
[
[
3
4
5
6
1
2
Serial number
CE labelling
Year of manufacture
Approved area of use
Inspection number
Manufacturer
1
2
3
4
5
6