MultiFlow Configuration of the MultiFlow
consisting of several products are processed individually. A separate
receipt is produced for each product.
If the OBC summary is activated, all products are combined on one
receipt. The maximum number of products per receipt is defined in this
case via parameter 3.1.5.2 ("Number of deliveries").
9.3.1.5
W & M Restrictions
Volume division: Number of post-decimal places on
volume display.
Maximum number of discharges per receipt.
Minimum default volume for discharge
(in increments of 200 liters)
Minimum requirement from W&M for bill / delivery
receipt
Determines whether the retrospective modification of
prices is permitted with measured products.
Separator for decimal places: '.' or ','
IMPORTANT: Parameter not currently active. See
parameter 3.3.3.3.
Definition of product used to flush the measuring
system.
Specification of the quantity of product used to flush
the measuring system
Minimum pre-set quantity after a product change (due
to product contamination) in liters. Specify according
to calibration regulations.
Monitors flushing of measuring system when
processing deliveries which have been transferred via
OBC.
0: No
1: Yes
2: Automatic
Determines the time after which a delivery is
automatically terminated when no flow is recognized.
Function inactive
1-99 Time limit in minutes
When active, actual delivery quantity is not displayed
during delivery.
Calibr
ation
super
-visor
Drive
r
Defines parameter protection for product density
0: Seal
1: Supervisor
2: Driver
9.3.1.5.1
Access density
The protection level for access to the density parameters in product
definition (3.5.x.x.7.4) can be specified via parameter 3.1.5.2.1. The
protection level for parameter 3.5.2.1 then automatically follows the