MultiFlow Configuration of the MultiFlow
MultiFlow AIII Wiring diagram
electronic control with flow control – (Belgian version)
+ dosage pump
+ overfill prevention amplifier
MultiFlow AI Wiring diagram pneum. control switch
+ dosage pump
MultiFlow AI Wiring diagram electronic control
+ dosage pump
+ overfill prevention amplifier
MultiFlow AI Wiring diagram
electronic control with flow control
MultiFlow AI Wiring diagram electronic control with flow control
+ dosage pump
+ overfill prevention amplifier
9.3.1.18.3
Notes on overfill prevention
Taking control of the servo component is sensible only during
simultaneous use of the automatic hose selection (see parameter
3.1.8.1).
9.3.1.18.4
Notes on blow down
Blow down of the dry hose is a function that is required only by the British
authorities. At the end of a discharge high pressure air is blown through
the dry hose for a set time to completely empty the hose.
Because the controller differs, only special full electronic hose selection
(parameter 3.1.8.1 = 5) can be used in the UK. With manual hose
selection the MultiFlow would be unable to decide whether a dry hose
was in use and therefore whether blow down was to be activated.