MultiFlow  Printing out Reports
Event
Data
Meaning
Class1 Memory Test
Self test: Working memory defective.
Class2 Memory Test
Self test: Working memory defective.
Class3 Memory Test
Self test: Working memory defective.
Display Com.
Communication error with the display.
W&M Printer
Communication error with the FDW printer.
Parameter Error
Setup defective.
CAN-Bus Error
Communication error on the CAN bus.
Master ????
Unknown master error.
Parameter Alarms:
ALARM
Product Setup
The setup is defective in the area of the products
(35xx).
Meter Setup
The setup is defective in the area of the equipment
settings.
Printer Setup
The setup is defective in the area of the printer
settings.
Sensor Setup
The setup is defective in the area of the sensors.
Form Setup
The setup is defective in the area of the form layout.
Meter Alarms:
ALARM
Temperature
A product temperature lies outside the permitted
range or an impermissible jump in temperature.
Temp-Limit
Pulse Error
A pulse error has been registered. (A and B pulses
differ)
Neg. Volume
An impermissible reverse flow has been registered.
Pulse-Sensor
A functional error in the pulse sensor has been
registered.
Power Fail
The supply voltage monitor has detected an
unexpected failure of power.
Additive Cycle
The additive pump was unable to carry out a complete
pump cycle within the prescribed time period.
Additive Speed exceeded
For the current product flow an additive pump rate has
been determined that the pump cannot fulfill.
Additive Empty
The internal level sensor of the additive pump has
signaled "empty".
Ext. Additive Empty
The external level sensor of the additive pump has
signaled "empty".
Additive: Start Position
The monitoring of the pump piston has not detected
the start position.
Additive: Piston Position
The monitoring of the pump piston has not detected
the start position.
Hose: Illegal Selection
The operator has made an impermissible hose
selection (only in the case of fully electronic selection).