14.9.6
Version 3.15
•
Support of the metering of additives after the measuring system, i.e.
the additive is separately shown on documents (delivery receipt,
invoice, trip report etc.)
This function is currently only active in the Belgian version.
•
Support of self loading and product transfer between the individual
chambers in a vehicle (product transfer) incl. receipts, saving in the
logbook, documentation in the events report etc.
This function is currently only active in the UK version.
14.9.7
Version 3.20
•
In the control variants with flow control the changeover from low to
high flow now takes place either with dependence on the flow quantity
or the flow rate.
•
The automatic adaptation of the preset switch-off (parameter 31843 –
31845) can be switched off with the new parameter 31846.
•
From version 3.20 on, the MultiFlow offers the option of querying the
payment status after an invoice has been printed.
14.9.8
Version 3.30
•
Support of a new controller variant for the assembly of measurement
systems with turbine
•
Logbook entry during modification of date and/or time
•
Support of a 64KByte chip card for parameters and data
•
Support of the Multi-IO for expansion of the inputs and outputs
•
The use of an ASCII printer driver enables e.g. the connection of a
laptop for the storage and archiving of parameter lists, log books, etc.
•
From Version 3.30 on, new auxiliary displays for density, meter factor
and mass are available during the discharge.
14.9.9
Version 3.40
•
Suppression of manual discharges during EMIS or TMC operation
•
Logbook: matching of the START and STOP times to the actual
product flow
•
Measurement system with turbine: New parameters for maximum flow
and residual volume in each product register
•
Operation of the MultiFlow without printer
•
Delivery receipt: New form elements for totals status and average flow
rates
•
Expansion of the logbook capacity