EasyManua.ls Logo

TechnipFMC Sening MultiFlow - Page 54

TechnipFMC Sening MultiFlow
356 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60
Sening® is a registered trademark of FMC Technologies
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Initial Operation
The following assignments are normal (further options in chapter 9.3.1.8
"Valve Control" / page 145):
1
Basic
Control
2
Flow
Control
3
Fully
Electronic
Control
4
Expanded
Electronic
Control
5
With blow
down
6
Exp.
electron.
BE
Output 1
Control air
LOW Flow
Wet hose
Wet hose
LOW flow
Wet hose
LOW flow
Wet hose
LOW flow
Output 2
Interlock
HIGH Flow
Dry hose
Dry hose
LOW flow
Dry hose
LOW flow
Dry hose
LOW flow
Output 3
ADD pump
Release
control switch
ADD pump
Wet hose
HIGH flow
Wet hose
HIGH flow
Wet hose
HIGH flow
Output 4
--------
ADD pump
Bypass
Dry hose
HIGH flow
Dry hose
HIGH flow
Dry hose
HIGH flow
Output 5
--------
--------
Position 1
Dual hose
outlet nozzle
Position 1
Dual hose
outlet nozzle
ADD pump
Position 1
Dual hose
outlet nozzle
Output 6
--------
--------
Position 2
Dual hose
outlet nozzle
Position 2
Dual hose
outlet nozzle
--------
Position 2
Dual hose
outlet nozzle
Output 7
--------
--------
Unmeasured
Unmeasured
Blow down
ADD pump
Output 8
--------
--------
--------
--------
--------
--------
Output 9
--------
--------
--------
--------
--------
--------
Output 10
--------
--------
--------
--------
--------
--------
Output 11
--------
--------
--------
--------
--------
--------
Input 1
ADD pump
rest position
ADD pump
rest position
ADD pump
rest position
--------
ADD pump
rest position
ADD pump
rest position
Input 2
ADD pump
end position
ADD pump
end position
ADD pump
end position
--------
ADD pump
end position
ADD pump
end position
Input 3
ADD pump
filling level
ADD pump
filling level
ADD pump
filling level
--------
ADD pump
filling level
ADD pump
filling level
Input 4
Overfill
prevention
amplifier
Overfill
prevention
amplifier
Overfill
prevention
amplifier
Overfill
prevention
amplifier
Product
Transfer &
Self Loading
Overfill
prevention
amplifier
Input 5
--------
--------
--------
--------
--------
--------
Input 6
--------
--------
--------
--------
--------
--------
Input 7
--------
--------
--------
--------
--------
--------
Input 8
--------
--------
--------
--------
--------
--------
Output 1.. 7: MultiFlow Input 1..4: MultiFlow
Output 8..11: MFIO-E Input 5..8: MFIO-E