66
Sening® is a registered trademark of FMC Technologies
MN F09 002 US  DOK-383E  Issue/Rev. 3.65 (02/24)
MultiFlow  Initial Operation
Menu 4.3.4, discharge
Status of the overfill prevention
Status of the dead man’s switch
Last incoming telegrams
of the various types
Pre-set amount for test of
the remote control
The connection is broken using <F3> and the MultiFlow is in the state
described at the beginning (idle).
5.7.4.2
Message meanings
KEY
Meaning
Start
Start / resumption of a discharge
Stop
End of a discharge
Volume
Change to a volume display during a discharge
Flow
Change to a flow display during a discharge
+
Increase pre-set value by 100
-
Reduce pre-set value by 100
++
Increase pre-set value by 1000 (SHIFT +)
--
Reduce pre-set value by 1000 (SHIFT -)
SHIFT
Shift key has been pressed
PULSE
Dead man’s key has been pressed
&PULSE
Shift key and dead man’s key have been pressed
simultaneously
&NOTSTOP
Shift key and emergency off key have been pressed
simultaneously
&Start
Shift key and start key have been pressed simultaneously
(motor start)
&Stop
Shift key and stop key have been pressed simultaneously
(motor stop)
&Vol
Shift key and volume key have been pressed
simultaneously
&Flow
Shift key and flow key have been pressed simultaneously
Rem ot e Co nt ro l
Le ve l Pr ob e +
( YE S, N :0 , 1. 8s )
De ad ma n Sw it ch +
( Y ES , N: 0, 1 .8 s )
S GN : RE L
K EY : Fl ow
S TS : LN K
( Dro p)
T es ti ng
Am ou nt : 15 00
Lin k S ta rt Di sco n

Table of Contents