The EPE2 is connected to the MultiFlow’s external CAN bus. A
connection to the EPE2 via the CAN bus is required in order to control
the EPE2. This connection can be established for test purposes using
key 1 and/or broken using key 3.
The EPE2 has one output. The status of this output can be changed
during the test using key 2. The EPE2 also has one further input.
Current statuses (connection, input and output) are shown in the central
section of the display.
5.7.6
IO Interface
Menu 4.3.7 contains the diagnostic functions for the IO interface (8
outputs, 2 inputs). It gives an overview of the current statuses of the
inputs and outputs of the external interface module.
This menu item can be accessed only when the connection to the IO
interface is active.
Diagnosis Menu 4.3.7
Outputs →
Inputs →
Status →
System messages →
The eight outputs can be switched by pressing the corresponding
number (1-8). In the case of outputs allocated to a hose path in the
configuration of the IO interface, this is possible only when the electronic
seal is broken.
The <F3> button queries the version number of the IO interface.