Bus configuration menu
Use the Bus menu to select the bus type to display
, configure the input sources, and set how to display the bus on the screen.
To open the Bus configuration menu:
For an existing bus, double-tap the Bus badge in the Settings bar.
To add a new Bus badge on the Settings bar, tap the Math Ref Bus > Add New Bus button. This adds the Bus badge to the Settings
bar and opens the Bus configuration menu.
Bus configuration menu - fields and controls
Field or control Description
Display Toggles bus display On or Off.
Label Enter label text in this field. The default label is the name of the bus type.
Position Sets the vertical position of the bus waveform. Default is 0 (center of graticule).
Set to 0 Sets the vertical position of the bus waveform to 0 (center graticule).
Results Table Sets the results table as On or Off to see the active measurements, bus decode activity
, and search
results in a spreadsheet format. Default is off.
Bus Type Select a bus from the drop down list. The Parallel bus type comes standard on the instrument. Serial
buses require purchase and installation of serial bus triggering and analysis options.
Source configuration A set of fields and controls that set the bus signal input parameters. Shown fields depend on the
selected bus type. See the individual bus configuration help topics for information on their settings.
Display format Enables showing just the decoded bus or both the bus and its digital waveforms. You can also tap on
the + symbol on the bus waveform to toggle between showing the bus only or showing bus and source
waveforms.
Decode format Sets how decoded data information is shown in the bus. Select from listed formats. Available formats
depend on the bus type.
Bus type configuration menus
Use the following links to access information on specific Bus configuration menus.
CAN serial bus configuration menu on page
133
I2C serial bus configuration menu on page 129
LIN serial bus configuration menu on page 136
NFC serial bus configuration menu
Parallel Bus configuration menu on page 127
RS232 serial bus menu on page 132
SENT serial bus configuration menu on page 137
SPI serial bus configuration menu on page 130
Parallel Bus configuration menu