Field or control Description
Rectangle Sets the shape of the mask to a rectangle
Trapezoid Sets the shape of the mask to a trapezoid.
Hexagon Sets the shape of the mask to a hexagon.
Custom Sets the shape of your choice.
Create Duplicate Creates a new segment with the same characteristics.
Configure Segment Opens the Mask Definition configuration menu for the selected segment.
Delete Segment Deletes the selected segment.
Delete All Deletes all segments associated with the mask.
Tolerance Mask controls
Field or control Description
Configure Mask Opens the Mask Definition configuration menu for the selected mask.
Delete Mask Deletes the selected mask.
Mask Test badge configuration menu
Use the Mask T
est badge menu to edit the settings of a mask test and define the actions to be taken according to the results.
To open the Mask Test badge configuration menu, double-tap on the badge.
A Mask Test badge is created when the first segment of a mask is defined.
Test Settings panel fields and controls
Field or control Description
Mask Test Turns the mask test On or Off.
Mask Display Turns the mask display On (default) or Off.
Label The text field to add a label to the mask test badge. By default, this field is blank.
When you recall a mask from a file, the name of the file is automatically displayed in the label field.
Source Lists the valid source signals for mask testing. Valid sources do not include other sources that are
already being used in mask tests.
Show segment hits in badge A checkbox to display the hits on each segment in the badge. By default, the setting is unchecked.
Number of Waveforms The numeric field to define the number of waveforms to test against. This value is shared amongst all
mask tests. Changing the value in one badge changes it in all mask test badges.
This field can be used along with the Single / Seq Stops After control to run a mask test with 100
waveforms ten times.
Total Failures The numeric field to set the failure threshold in number of acquisitions. The value must be greater than
or equal to Consecutive Failures.
Consecutive Failures The numeric field to set the failure threshold in number of consecutively failing acquisitions. The value
must be less than or equal to T
otal Failures.