Field or control Description
Source Select the SPI bus that you want to search.
Mark On Select the type of information for which to search.
Search Source Set the search source. Set either MOSI or MISO.
A
vailable when Mark On is SS Active.
Data Words Sets the number of data words defined based on the word size in bus configuration. If the word size in
bus configuration is 4, then data words will go to 32.
Maximum data words is word size <=128.
Available when Mark On is Data.
Data Sets the data pattern for which to search. The number of bits shown depends on the Data Words
setting.
Tap the Binary or Hex field and use the A and B knobs to select and change the values. Or double-tap
on the field and use the virtual keypad to enter values.
Available when Mark On is Data.
A, B knob controls Use the A knob to select (highlight) the digit(s) to change.
Use the B knob to change the value of the digit(s).
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
See also
Bus T
rigger configuration on page 220
Bus Search configuration menus on page 139
SPI serial bus configuration menu on page 130
RS-232 serial bus search configuration menu
Use the RS-232 Search configuration menu to define conditions to search for and mark on an RS-232 bus waveform. You can have
multiple searches on the same bus.
Field or control Description
Display Enables or disables displaying search marks on this search.
Act on Event Tap the Act on Event button to configure the actions the instrument must take when a search event
occurs. See Act On Event configuration menu on page
105 for the available fields and controls.
Results Table Sets the results table as On or Off to see the active measurements, bus decode activity, and search
results in a spreadsheet format. Default is off.
Search Type Set to Bus.
Source Select the RS232 bus that you want to search.
Mark On Select the type of information for which to search.
Table continued…