2. Use the menu selections to set horizontal parameters.
3. T
ap the Help icon on the menu title for more information on these settings.
How to trigger on a signal
Use this procedure to open the Trigger menu to select and configure the trigger event type and conditions.
1. Double-tap the Trigger badge on the Settings bar to open the Trigger configuration menu.
2. Select a trigger from the Trigger Type list. The trigger type sets what fields are available in the menu and also updates the illustration
to show a graphic of the trigger type.
To trigger on a bus, you must first add the bus to the Waveform view. See Add a math, reference, or bus waveform on page
62
Note: T
riggering on buses other than Parallel requires purchasing and installing serial trigger and analysis options.
3. Select the other fields and panels to refine the trigger conditions. The menu fields and trigger graphic updates as you make changes to
the trigger settings. Displayed fields depend on the selected trigger type. Selection changes take ef
fect immediately.
Analog channel operating basics
2 Series MSO MSO24 and MSO22 59