Field or control Description
Error Type Sets the error type for which to search and mark on the bus waveform. (Missing Ack, Bit Stuffing, or
Any Error.
A
vailable when CAN Standard is in CAN 2.0 + FD (ISO) + XL, CAN 2.0, or CAN FD (ISO) from CAN
bus configuration menu and Mark On is set to Error.
A, B knob controls Use the A knob to select (highlight) the digit to change.
Use the B knob to change the value of the digit.
Copy Trigger Settings to
Search
Sets the search criteria to match the current oscilloscope trigger settings.
Copy Search Settings to
Trigger
Sets the current oscilloscope trigger settings to match the search criteria.
See also
Bus T
rigger configuration on page 220
Bus Search configuration menus on page 139
CAN serial bus configuration menu on page 133
CAN DBC Symbolic Configuration menu
Use this menu to set the CAN .dbc symbol definitions for which to search. This menu is accessed from a CAN Bus Search menu when
a .dbc symbol definition file is loaded on the instrument. Load the .dbc file when you first add and configure the CAN bus.
Field or control Description
Symbolic Type Sets whether to search for Message CAN or search on both Message and Signal code.
Message Sets the CAN message label for which to search. Use the drop-down list to select from message labels
derived from the installed .dbc file.
Signal Sets the CAN signal label for which to search. Use the drop-down list to select from signal labels
derived from the installed .dbc file.
Signal Encoded Enables searching for encoded signal values (when selected) or specific values (when not selected).
Use the drop-down list to select from encoded signal types derived from the installed .dbc file.
V
alue searching is always available for a signal. Signals, however, are not necessarily encoded, so
searches on signal encoding are not always available.
Value Sets a specific Signal value for which to search. Use knob A to set a value, or double-tap the field and
enter a value using the virtual keyboard.
See also
CAN serial bus search configuration menu (when using a .dbc symbol definition file) on page 145
CAN serial bus configuration menu on page 133
CAN serial bus configuration menu on page 133
Menus and dialog boxes