EasyManua.ls Logo

Tektronix MSO 2 Series - Page 71

Tektronix MSO 2 Series
275 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
b. T
ap the Clock Source field and select the source for the parallel bus clock signal.
c. Tap the Polarity and Threshold controls and set the clock signal transition to detect and threshold level, respectively.
3. Tap Define Inputs and select the signal sources for the parallel bus. Signal sources can be analog, math, or reference. Tap a signal in
the Sources list to add it to the bus list on the left.
For 8 channel:
For 16 channel:
The bus waveform updates as you make changes on the configuration menu. Tap the + symbol next to the waveform handle to turn on
and of
f showing the signals associated with the bus waveform.
4. Use the rest of the fields and controls in the configuration menu to set up the parallel bus parameters (label, position, display and
decode formats).
5. Tap outside of the Bus configuration menu to close it.
6. To get a stable triggered waveform, double-tap the Trigger badge, set the Trigger Type to Bus, select the bus Source to the parallel
bus you just set up, and enter the data condition on which to trigger in the Data field.
7. For information on parallel bus menu settings, tap the Help button on the Bus configuration menu.
Analog channel operating basics
2 Series MSO MSO24 and MSO22 71