5.3 Reference Guide using RS-232C commands
104
CONF:SYS:TESTER:ENCRYPTION <Value>
Description
This command sets Encryption parameter of LMP feature. If this value is set ON’, ‘encr of LMP feature is
displayed as ‘1’.
Value
encryption : ON(default), OFF
READ:SYS:TESTER:NAME_DISCOVERY?
Discription
This command reads the User Friendly Name which is got during Discovery procedure.
CONF:SYS:TESTER:NAME_DISCOVERY <Value>
Description
This command sets whether the User Friendly Name is read or not by tester.
Value
Name_discovery : ON(default), OFF
READ:SYS:TESTER:PAUSE_TEST?
Discription
This command reads the Pause parameter.
CONF:SYS:TESTER:PAUSE_TEST <Value>
Description
This command sets Pause parameter.
Value
Pause_test : ON, OFF(default)
READ:SYS:TESTER:INIT_AUTHN?
Discription
This command reads the setting parameter of Init authentication.
CONF:SYS:TESTER:INIT_AUTHN <Value>
Description
This command to set whether to enable or disable the ‘Init authentication’ parameter.
Value
Pause_test : ON, OFF(default)
READ:SYS:DUT:HCI_TYPE?
Description
This command reads the number of ports and the type of HCI transport layer of a DUT.
CONF:SYS:DUT:HCI_TYPE <Value>
Description
This command writes the number of ports and the type of HCI transport layer of a DUT
Value
HCI Type : NONE(default), USB1, USB2, RS1, RS2, UART1, UART2, BCSP1, BCSP2, 2WIRE1, 2WIRE2

Table of Contents