3 Getting Started
36 FM-750 Display User Guide
Refill
Use this option to view and adjust the following settings:
Section Switching Setup
Use this option to view and adjust the following settings:
Boundary switching overlap
Use this option to control the amount of overlap on a boundary before the system
switches off the boom section. Enter a percentage between 1-99%.
Note – This setting only operates when the boom is overlapping a headland, or pivot
boundary, or exclusion zone.
For:
• Less skip: Set a high percentage when it is acceptable to apply outside the
boundary.
• Less overlap: Set a low percentage when you do not want to apply outside the
boundary. A very low setting may cause some skip at the boundary.
Setting ... Notes ...
Current volume Set the current volume of the tank or bin.
Refill method Choose from one of the following options:
• Refill: to fill the tank or bin to the top
• Partial Refill: to add a specified amount to the tank or bin when
you select
Partial Refill Now from the Refill screen.
Refill Now / Partial Refill Now Use this option to refill the tank or bin.
Setting ... Notes ...
Coverage switching overlap Control the amount of boom switching overlap allowed before the
system switches that section.
Enter a percentage between 1-99%.
For:
• Less skip: Set a high percentage when total coverage is essential.
The system will turn off sections when they cover a larger
percentage of any fully covered areas. This may cause some
double-coverage. Sections will turn on as soon as they move from
a covered to an uncovered area.
• Less overlap: Set a low percentage when you need to save
product. The system will turn off sections as soon as you reach any
covered area. This may leave some skips. Sections will turn on
when the entire section has moved from a covered to an
uncovered area.
Refill method Choose from one of the following options:
• Refill: to fill the tank or bin to the top
• Partial Refill: to add a specified amount to the tank or bin when
you select
Partial Refill Now from the Refill screen.
Refill Now / Partial Refill Now Use this option to refill the tank or bin.