Do you have a question about the Trimble FM-1000 and is the answer not in the manual?
Battery Life | Up to 8 hours |
---|---|
Touchscreen | Yes |
Operating Temperature | -20°C to 60°C |
Storage Temperature | -30°C to 70°C |
Power Supply | 12-24 VDC |
Display Size | 12.1 inch |
Display Type | LCD |
Operating System | Windows Embedded Standard 7 |
Connectivity | USB, Ethernet, Bluetooth |
GPS | Integrated |
Provides an overview of the FM-1000 integrated display's capabilities and features.
Details firmware and user guide updates for version 9.25, revision B.
Instructions on how to power the display on and off, including proper shutdown procedures.
Overview of the five main screens used for setup and operations, including access to help.
Explains access and administration passwords, including how to change the administration password.
Details on purchasing, installing, unlocking, and activating optional features and plugins.
Details on how to unlock features and services using passcodes and firmware updates.
Instructions on activating unlocked features and plugins for system use.
Guides users through configuring essential system settings like CAN bus and language.
Overview of data management tasks including transferring, deleting, and editing data.
Explains how to transfer data between USB drives, the display, and computers.
Details the folder structure for storing client, farm, field, and event data on USB and computer.
Configuration options for GPS receivers, including correction services like CenterPoint RTX.
Guides users on setting up remote output signals to control external devices like tree planters.
Details on configuring the FM-1000 to receive and log NMEA messages from external devices.
Defines settings for field features like points, areas, and lines for on-screen indication.
Configures how features are placed in relation to the boom center, right, or left.
Step-by-step instructions for creating new area, line, or point features in the field.
Ensures the system knows the implement type, area coverage, and offset from guidance line.
Guides users through creating a new implement configuration, including selecting features.
Allows modification of implement type, measurements, geometry, overlap, and extras.
Covers manual guidance, Autopilot, EZ-Pilot, and EZ-Steer systems, all requiring GPS.
Setup and calibration procedures for the Autopilot automated steering system.
Details on setting up and calibrating the EZ-Pilot assisted steering system.
Explains how Field-IQ performs automatic section control and rate control using prescriptions.
Guides on adding, editing, and deleting materials, including alarm settings.
Details on setting up new control locations and managing assigned modules.
Explains how GreenSeeker sensors measure plant NDVI and send data for rate control.
Provides best practices for maintaining GreenSeeker performance and system longevity.
Instructions on establishing a nitrogen-rich reference strip (NRS) for nitrogen application.
Guides on setting up ISOBUS features, including connecting the CAN bus and activating plugins.
Instructions for accessing and setting up the Virtual Terminal for equipment control.
Details on setting up Task Controller for controlling implement operations via ISOBUS.
Lists variable rate controllers supported by the FM-1000 display for serial rate control.
Guides on configuring settings for various variable rate controllers like Amazone, Hardi, Raven.
Specific setup instructions for connecting and configuring the Hardi 5500 or 6500 controller.
Explains how TrueGuide uses a second GPS receiver for implement guidance accuracy.
Guides on setting up and selecting a new or existing implement for TrueGuide guidance.
Steps to calibrate the TrueGuide system, including ensuring a field and AB line are configured.
Overview of the TrueTracker feature for active implement steering and accuracy.
Detailed steps for activating TrueTracker, completing implement controller settings, and calibration.
Procedures for calibrating the implement's steering sensor, deadzone, and proportional gain.
Explains how Vehicle Sync transfers data wirelessly between vehicles for operational efficiency.
Guides for setting up Vehicle Sync, including channel, IP, and display name configuration.
Overview of Water Management features including survey, design, leveling, and WM-Drain.
Steps for creating field surveys and designs, including benchmarks and boundary definition.
Instructions for setting up WM-Drain for implement control, limits, and valve calibration.
Explains how Yield Monitoring views, maps, and records crop yield and moisture data.
Key practices for installing and setting up the Yield Monitoring system for optimal results.
Guides to configure combine, operation, crop, map, sensor output, and options settings.
Common user work operations performed at the Run screen, including basic steps.
Information on organizing work by client, farm, field, and event, and creating/selecting fields.
Explains how to create and use guidance patterns like straight, curved, headland, and FreeForm.
Provides information on advanced system diagnostics, CAN bus, network, and serial communications.
Details on viewing guidance, steering, faults, and warnings for Autopilot system diagnostics.
Troubleshooting guide for Field-IQ system faults, including section control and sensor issues.
Definitions of terms starting with 'A', such as A+ line, AB line, Accelerometer, Access path, Aggressiveness, Autonomous GNSS positioning.
Definitions of terms starting with 'B', such as Benchmark.
Definitions of terms starting with 'C', such as CenterPoint, Clean grain elevator, Client, Composite slope, Controller orientation, Correction age.