Equipment calibration for Field-IQ 9 Field-IQ system setup
Note – Before priming the system, the Automatic / Manual Switch on the master switch box must be in
the manual position.
3.
Tap Drive Calibration and then tap OK. The Drive Calibration screen displays. Enter the
appropriate settings.
Tab Explanation
Drive Limits Enter the minimum and maximum flow values.
Auto-Tuning Moving parts during this operation. Ensure that the
implement is safe to operate.
Follow the on-screen instructions to auto-tune the system.
Do not perform the auto-tuning function if you have loaded
a preset configuration file. Use the predefined configuration
settings appropriate for your vehicle.
Drive Settings Turn the master switch on and vary the rates. Adjust values
if needed.
Info Shows the results and drive limits of your calibration.
4. Select Flow Calibration and then tap OK. The Flow Calibration screen displays.
Anhydrous calibration
WARNING NH3 is an irritant and corrosive to the skin, eyes, respiratory tract and mucous membranes, and is
dangerous if not handled properly. It may cause severe burns to the eyes, lungs, and skin. Skin, and respiratory-
related diseases could be aggravated by exposure. It is recommended that protective gloves, boots, slicker and/or
pants and jacket, and chemical-splash goggles that are impervious to anhydrous ammonia are worn at all times.
WARNING Anhydrous valve and flow calibrations require the vehicle and implement to be moving and the
implement must be in the ground (the implement lift switch must be down). Take all necessary precautions to
ensure user safety. Failure to do so may result in serious injury or death.
To calibrate anhydrous, first calibrate the implement lift switch. Then calibrate the modules to
ensure your system performs at the level you require.
Implement lift switch calibration
1. At the Field-IQ Calibration screen, select Implement Lift.
2. Raise the implement and then tap Next.
3. Lower the implement and then tap Next.
4. Tap OK to return to the Field-IQ Calibration screen.
230 FM-1000 Integrated Display User Guide Version 9.25, Revision B