17 Yield Monitoring setup Yield Monitoring best practices
Tilt angle Yield reading too high Yield reading too low
forward of center
sensitivity sensitivity
Backward pitch, sensor aft
of center
Increase backward pitch
sensitivity
Decrease backward pitch
sensitivity
Forward pitch, sensor
forward of center
Increase forward pitch
sensitivity
Decrease forward pitch
sensitivity
Forward pitch, sensor aft of
center
Decrease forward pitch
sensitivity
Increase forward pitch
sensitivity
To start, adjust the sensitivity numbers in increments of 0.2.
Test weight
The Yield Monitoring system measures the volume of grain passing through the combine, and
estimates the weight by multiplying the measured volume by the test weight. Therefore, an
accurate measurement of test weight is required in order to achieve an accurate total weight
measurement. To ensure the best results:
l Recheck the test weight whenever the field conditions change significantly, either when
harvesting different varieties, or when the moisture level of the crop changes.
l Take several samples of test weight on calibration loads, and use the average of these samples
when calibrating.
Calibrating and operating conditions
How you operate your combine can affect your accuracy. Consider the following:
l Calibration will be most effective if you operate your combine at the same conditions as you
used during calibration.
l Frequent starts and stops during a load could degrade the overall accuracy of the load.
Version 9.25, Revision B FM-1000 Integrated Display User Guide 327