9 Field-IQ system setup Control setup
Sensor tab
At the Sensor tab, you can add alarm functionality to a sensor. You can also access the Sensor Setup
screen, where you can add, edit, or delete sensors.
Setting Explanation
Sensor Type The required sensor for which you want to create an alarm.
Name Displays after you have selected the sensor type. You can enter a name
for the sensor.
Alarm
Enabled:Alarm is enabled
Disabled:There is no alarm
Warn if below If less than this threshold and longer than the delay time, the alarm will
display.
Warn if above If more than this threshold and longer than the delay time, the alarm will
display.
Warn after
Delay time for the threshold values:
l Warn if below
l Warn if above
Sensor Setup
Tap to access the
Sensor Setup
screen.
Sensor Setup screen
At the Sensor Setup screen, you can add, edit or remove a sensor.
When adding or editing a sensor, enter the following information.
Setting Explanation
Sensor Type
l Air pressure/vacuum
l Liquid pressure
l NH3 pressure
l Bin level
l RPM
l Gate Height
Name Enter a name for the sensor
Sensor Setup
Field-IQ module: The Field-IQ system module that is controlling this sensor.