19 Diagnostics Field-IQ diagnostics
The color coding for the sections are:
Section Number Tab Section Indicator Graphic Section is... Section switch
is...
Not indented Red Not armed Off
Not indented Gray Not armed On
Indented Red Armed Off
Indented Green Armed On
Testing section switches
Testing the switches from the Diagnostic screen is useful because you do not have to open a field or
set a manual speed and manual coverage to make the section switches active.
At the Operation tab:
1. Arm the sections by tapping on the box with the sections you want to turn on.
2. Flip the section switches to test that they are working properly and are in the correct order.
Hardware tab
On this tab, the control modules are listed with the:
l Serial number of the module
l Position on the implement
l Firmware version
l Status of CANconnection
l Tx/Rx number of packets
Row Monitor tab
The status column of this screen indicates:
l Disabled:Sensor is not detected.
l Off:Sensor is detected but is not actively looking for seed.
l On:Sensor is detected and is looking for seed. (The field is open with system planting.)
Version 9.25, Revision B FM-1000 Integrated Display User Guide 481