Trimble FM-1000 - Yield Monitoring warning messages

Default Icon
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19 Diagnostics Yield Monitoring diagnostics
Yield Monitoring warning messages
Warning message Explanation
Unable to calibrate yield monitor. Occurs when tare calibration fails.
Invalid selection. Please select one of the
calibration types below this item.
The user clicked on the wrong line in the Yield
Monitor Calibration menu.
No Connection. Please check connections. User attempted to calibrate a device that is not
connected.
Failed to detect yield sensor!!! Some setup parameters cannot be edited
because the yield monitor is not connected.
Yield sensor has not uploaded configuration
into FmX.
Some setup parameters cannot be edited
because they have not been received from the
yield monitor.
Trimble Yield Monitor not found—check cabling
and fuses—check Yield Monitor Setup.
Yield monitor not detected.
Trimble Moisture Sensor not found—check
cabling and fuses—check Yield Monitor Setup.
Moisture sensor not detected.
One or more Yield Monitor devices were
disconnected.
A device has been disconnected.
Moisture out of range. Check the sensor is
positioned properly and not being struck by
paddles, and there is no free water or wet soil
on sensor surface.
Bad reading received from moisture sensor.
The label cannot be oriented along the same
axis as the connectors.
Invalid selection in IMU sensor orientation
setup.
Choose the options that match the Trimble
Yield Monitor’s mounting orientation.
Attempting to perform roll calibration before
setting a valid orientation.
Would you like to calibrate the roll sensor?
For accurate Roll Offset calibration you must
turn the vehicle around.
User did not turn the vehicle around for second
step of roll calibration.
Please select one or more loads to use for
calibration. Tap the check mark to select a load.
Attempted to run load calibration with no loads
selected.
Would you like to apply the calibration to the
current field?