Yield Monitoring diagnostics 19 Diagnostics
Moisture Sensor Item Explanation
Sensor Value
Percent of moisture and the raw sensor value
Can be used by support or engineering if troubleshooting is
necessary.
Temperature
Yield Monitor error messages
State 1 - During boot up
Cause Actions
60 Series
Moisture unit
Head unit
Armrest unit
70 Series
Moisture sensor
CC1 unit
Cab unit
Corner post
YM 2000
Cannot detect YM 2000
Serial port
1. Ensure that the correct cable is installed.
2. Ensure the display is communicating with the CAN bus
(system / diagnostics / serial port / Port A/B). Is there
another value other than zero for CAN messages?
3. For 60 Series Combines: Check if Crop Type will change on
the Greenstar display after Crop Type on the FM-1000
integrated display has been changed.
4. For 70 Series Combines: Change the Crop Type in the
command center and make sure it changes on the FM-
1000 integrated display.
5. Raise the head up or down to see if the display will show a
change for header height.
6. If step 1 and step 2 resolve the issue, log field data.
508 FM-1000 Integrated Display User Guide Version 9.25, Revision B