16 Water Management setup WM-Drain setup
Calibrate the valve
WM-Drain performs its calibration sequence to test the speed at which the blade raises and lowers.
This process takes approximately 8 - 10 minutes for each valve.
1.
At the Home screen, tap . The Configuration screen displays.
2.
Select WM-Drain and tap Calibrate.
3. Select the appropriate valve (depth or pitch), if applicable.
4.
At the Depth ValveCalibration screen, set the vehicle throttle to 100% and tap Start.
Note – To manually calibrate the valve, enter values for manual calibration and tap OK.
5. When the procedure is complete, tap OK.
6. Repeat this procedure for another valve, if applicable.
Note – To stop the plow cylinders from working excessively when stopped, you can add a value for
Stopped
Deadband
.