9 Field-IQ system setup Control setup
Material tab
1.
On the Material tab at the Available Materials list, select the material that will be set up in this
location.
Setting Explanation
Material Type Select the type of material being applied:
ll Row Crop Seed
l Liquid
l Granular Seed
l Granular Fertilizer
l Anhydrous
Material Name Name of the material
Material Units Units to use with the selected material
Seeds Per Pound Number of seeds per pound
Target Rate 1
Preset volume that the implement supplies when the rate
switch is in position 1.
Note –
For liquid, granular fertilizer, NH3, and Granular seed,
enter the desired amount of material that you would like to apply.
For Row Crop seed, the target rate for row crop seed is entered as
Ks/a. 1 Ks/a equals 1000 seeds per acre. When entering a target
rate of 25500 into the
display
, type it as 25.5.
Target Rate 2
Present volume that the implement supplies when the rate
switch is in position 2.
Note –
For liquid, granular fertilizer, NH3, and Granular seed,
enter the desired amount of material that you would like to apply.
For Row Crop seed, the target rate for row crop seed is entered as
Ks/a. 1 Ks/a equals 1000 seeds per acre. When entering a target
rate of 25500 into the
display
, type it as 25.5.
Rate Increment
This setting adjusts the increment that the target rate will
adjust by when in rate 1 or 2.
Manual Rate Increment
Controls the aggressiveness of the rate adjustment switch
when in manual rate.
ll If the valve is over active when in manual rate you
Version 9.25, Revision B FM-1000 Integrated Display User Guide 215

Table of Contents