LH5000 12 Serial Rate Control setup
LH5000
To use the LH 5000 controller, you need a special adapter cable (LH Agro P/N198-701) to connect to
the cable P/N 67091.
1. Connect the FM-1000 integrated display to the LH5000 by either:
a. Connecting the special adapter cable (LH Agro P/N198-701) to connect to the display cable
(P/N 67091). Cable P/N 6709 will be connected to Port A or B on the display .
b. Connecting the display to the controller with an extension (straight through) serial cable.
2. Set up the controller, press:
a. Return
b.
Return
c.
Fertil.-Distrib
d.
Select Type
e.
LH5000
f.
Accept
Raven
To use a Raven controller with the FM-1000 integrated display, the controller must:
l Be GPS-ready
l Use Raven’s latest communications protocol (which was introduced in 1996).
If your controller is not GPS-ready or does not use the latest protocol, contact Raven for an upgrade
pack.
Cable P/N 6709 will be connected to Port A or B on the display . Cable P/N 6709 will be connected to
Port A or B on the display .
260 FM-1000 Integrated Display User Guide Version 9.25, Revision B