Amazone Amatron + 12 Serial Rate Control setup
Amazone Amatron +
1. Connect the FM-1000 integrated display to the Amazone Amatron +:
a. Connect the special adapter cable (P/N 59043) to the display cable (P/N 67091).
2. Set up the controller:
a. Press Shift + Page / Setup / Page 2.
b. Set RS232 to 57600 baud.
Bogballe Calibrator
To use the Bogballe Calibrator, you need a special adapter cable (P/N 59043) to connect to the cable
P/N 67091. Cable P/N 6709 will be connected to Port A or B on the display . Optionally, you can use
an extension (straight through) serial cable.
Note – The standoff nuts on the Bogballe rate controller may prevent the pins in the cable connector from
making a connection. In this case, remove the standoff nuts.
Controller setup
To set up the controller to operate correctly with the FM-1000 integrated display, tap:
1.
Return
2.
Return
3.
Fertil.-Distrib
4.
Select Type
5.
Bogballe E/EX
6.
Accept
Flex-Air setup
The FM-1000 integrated display can send rates to the Tyler Flex-Air variable rate controller. The
controller can have four channels
l Main
l Liquid
l Co-applicator
l Supplemental
258 FM-1000 Integrated Display User Guide Version 9.25, Revision B