EasyManua.ls Logo

Trimble FM-1000 - Implement Steering Sensor calibration

Default Icon
524 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Implement calibration for TrueTracker system 14 TrueTracker setup
Implement Steering Sensor calibration
Note – Complete this calibration before you calibrate the Automated Steering Deadzone or Antenna Roll
Correction.
This calibration converts the voltage output of the steering sensor into an equivalent steering angle
measurement.
Note – This calibration is only available for implements that have a steering sensor providing feedback for the
steering mechanism location. Sideshift hitches do not use this calibration.
Make sure that you:
l Perform this procedure on a level surface that is free of obstructions.
l Follow the instructions on each page.
l Run the engine at full throttle.
l Raise the implement.
Calibration steps
1. At the Implement ControllerCalibration screen, select Implement Steering Sensor Calibration. The
Implement Steering Sensor Calibration screen displays.
2.
For vehicles with coulters, make sure they are raised out of the ground. For other articulation
methods, make sure the vehicle is slowly moving forward in a wide open space to allow free
movement of the steering mechanism.
3. Tap Start.
4. Perform the calibration. The system will automatically steer to the right and to the left. The
value for Volts updates as the wheels are steered.
284 FM-1000 Integrated Display User Guide Version 9.25, Revision B