12 Serial Rate Control setup Raven
Configure the controller
Data menu
Settings Additional Information
l BAUD: 9600
l GPS: Inac
l DLOG: ON
l TRIG: 1
l UNIT: Sec
Some Raven controllers may lose the settings if power is
disconnected. You must then reconfigure the controller.
Implement Boom Setup
Settings Additional Information
Application width:
l First boom section width must
be greater than 0, otherwise the
display will not communicate
with the controller.
l Total boom section width must
match the Application Width setting
in the
Implement Boom Setup
screen.
The display varies the width of the coverage polygons
according to the number of boom sections, but it does
not know the absolute width of each boom section. It
only knows the relative width of each boom section with
respect to the total boom section width.
When recording coverage polygons, each section is
considered to be a percentage of the application width
set in the Implement Boom Setup screen. For example, if
you create an intentional overlap to avoid gaps in the
application coverage by making the application width
greater than the swath width. This proportionally
changes the recorded width of each boom section.
Channel Setting
Settings Additional Information
To allow rates sent by the display to
be used by the Raven controller, set
channel to either:
l Rate 1 (SCS4XX, SCS6XX)
l Product X Auto (SCS7XX)
If the controller is set to
Rate 2
or
Manual
, the controller
ignores the rates being sent, but the
display
still records
the applied rates.
Version 9.25, Revision B FM-1000 Integrated Display User Guide 261