FM-750 Display User Guide 37
Getting Started 3
On/off valve latency
This option allows for hardware delays by adjusting the amount of time needed before
turning the valves on or off.
To use this option:
1. Measure the amount of time it takes (in seconds) for the system to reach the
correct rate after you have switched it on or off.
2. Enter a time between 0.0 - 10.0 seconds.
Intentional overlap
You can use this option to make sure that when applying, there are no gaps in coverage
if you move into an uncovered area or out of a covered area.
Target rate
Use this option to set the target application rate (the amount of product you want to
apply). Enter a number between 1333 - 41333.
Valve aggressiveness
If you use an auto steer system, such as an EZ-Steer or Autopilot system, you can use
this option to adjust how the system responds to steering changes.
Note the following:
• A higher setting brings the vehicle back on line quickly, but may cause tight
oscillations.
• A lower setting gives a more moderate response to bringing the vehicle back on
line, but can avoid overshoot.
Enter a setting between 50 - 150%.
The Field icon
From the guidance screen, tap to create a new field or select an existing field.
See Chapter 6, Mapping and Guidance.
Use this option ... To set the distance that you want to travel before...
On overlap distance Exiting a covered area and switching the implement on
Off overlap distance Entering a covered area and switching the implement off